Part #:AF16-30-10-12
SKU #: 2233215
Key Features
Part #:AF16-30-10-12
SKU #: 2233215
Brand: ABB
Coil Power Rating: 5 hp, 10 hp, 15 hp, 1-1/2 hp, 3 hp
Coil Voltage: 48 to 130, 48 to 130 VAC/VDC
Contact Configuration: 3NO
Contact Rating: 30 A at 690 V
Dimensions: 45 mm W x 77 mm D x 86 mm H
- Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
- Can manage large control voltage variations
- Reduced panel energy consumption
- Very distinct closing and opening
- Built-in surge suppression
- Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
- 30 A at 690 V, 26 A at 690 V rated operational current AC-1
- 18 A at 220/230/240 V, 18 A at 380/400 V, 18 A at 415 V, 18 A at 440 V, 15 A at 500 V, 10.5 A at 690 V rated operational current AC-3
- 5 hp at 220 to 240 VAC 3 ph, 10 hp at 440 to 480 VAC 3 ph, 15 hp at 550 to 600 VAC 3 ph, 1-1/2 hp at 120 VAC 1 ph, 5 hp at 200 to 208 VAC 3 ph, 3 hp at 240 VAC 1 ph
- 4 kW at 220/230/240 V, 7.5 kW at 380/400 V, 9 kW at 415 V, 9 kW at 440 V, 9 kW at 500 V, 9 kW at 690 V
ABB AF16-30-10-12 Line Contactor
ABB Line Contactor, Non-Reversing, Series: AF Series, 48 to 130 VAC/VDC Coil, 30 A Maximum Load Current, 5 hp, 10 hp, 15 hp, 1-1/2 hp, 3 hp Coil, 3 Pole, 4/7.5/9 kW Wattage, 3NO Contact Configuration, 1NO Auxiliary Contacts, 30 A at 690 V Contact, AF16 Size, Screw Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 45 mm W x 77 mm D x 86 mm H Dimensions
Additional Description: ABB -AF16-30-10-12 AF16 3P CONTR, 1NO, 48-130VAC/DC
Catalog Description: AF16 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC o