Part #:AF96-30-11-41
SKU #: 2296749
Key Features
Part #:AF96-30-11-41
SKU #: 2296749
Brand: ABB
Coil Power Rating: 30 hp, 60 hp, 75 hp, 7-1/2 hp, 20 hp
Coil Voltage: 24 to 60, 24 to 60 VAC
Contact Configuration: 3NO
Contact Rating: 130 A at 690 V
Dimensions: 82 mm W x 116 mm D x 125.5 mm H
- Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
- Can manage large control voltage variations
- Reduced panel energy consumption
- Very distinct closing and opening
- Built-in surge suppression
- Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
- 130 A at 690 V, 105 A at 690 V, 90 A at 690 V rated operational current AC-1
- 96 A at 220/230/240 V, 96 A at 380/400 V, 96 A at 415 V, 96 A at 440 V, 80 A at 500 V, 57 A at 690 V, 30 A at 1000 V rated operational current AC-3
- 30 hp at 220 to 240 VAC 3 ph, 60 hp at 440 to 480 VAC 3 ph, 75 hp at 550 to 600 VAC 3 ph, 7-1/2 hp at 120 VAC 1 ph, 30 hp at 200 to 208 VAC 3 ph, 20 hp at 240 VAC 1 ph
- 25 kW at 220/230/240 V, 45 kW at 380/400 V, 55 kW at 415 V, 55 kW at 440 V, 55 kW at 500 V, 55 kW at 690 V, 45 kW at 400 V
ABB AF96-30-11-41 Line Contactor
ABB Line Contactor, Non-Reversing, Series: AF Series, 24 to 60 VAC Coil, 115 A Maximum Load Current, 30 hp, 60 hp, 75 hp, 7-1/2 hp, 20 hp Coil, 3 Pole, 50/60 Hz Frequency, 25/45/55 kW Wattage, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 130 A at 690 V Contact, AF96 Size, Screw Terminal, IP10/IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 82 mm W x 116 mm D x 125.5 mm H Dimensions
Additional Description: ABB -AF96-30-11-41 (O)(N) CTR,3P,92A,24-60VAC,1/1 NON-CANCELABLE, NON-RETURNABLE
Catalog Description: AF96 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with side-mounted 1 N.O. + 1 N.C. auxiliary contact block, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contac